Showing all 12 results

Energy Meters

download pdf file [su_table][su_table] OUTPUT RS485 communication, protocol JBUS/MODBUS FORMAT 96x96 mm CURRENT 1 and 5 A VOLTAGE 190...440 V (phase-phase) VOLTAGE OPTIONS direct CURRENT OPTIONS from CT (programmable ratio) TYPE Multifunction CT connected active (class 1) and reactive (class 2) energy meter MAIN single or three-phase 3/4 wire balanced or unbalanced load AUX Selfsupplied [/su_table]

Energy Meters

download pdf file [su_table][su_table] OUTPUT pulses (Wh or varh) FORMAT 72x72 mm CURRENT 1 and 5 A VOLTAGE 80...150 V (phase-phase) VOLTAGE OPTIONS da TV (rapporto programmabile) CURRENT OPTIONS from CT (programmable ratio) TYPE Multifunction CT connected active (class 1) and reactive (class 2) energy meter MAIN single or three-phase 3/4 wire balanced or unbalanced load AUX Selfsupplied [/su_table]

Energy Meters

download pdf file [su_table][su_table] OUTPUT pulses+RS485 FORMAT 6 DIN module CURRENT 10 (100) A VOLTAGE 400…415 V VOLTAGE OPTIONS direct CURRENT OPTIONS direct TYPE Conto D6 Three phase + neutral Energy Meter, direct input 100A - pulse output SO - RS485 communication output MAIN three-phase 4 wire unbalanced load AUX Selfsupplied [/su_table]

Energy Meters

download pdf file Three-phase 3 wire network Direct connection: 230V and 400V Three-phase 4 wire network Direct connection: 230(400)V 63A Programmable pulse output RS485 communication Sealable housing and terminal block External interfaces: Ethernet communication (NT809-NT891) RS232 communication(NT693)

Energy Meters

download pdf file Three-phase network 3 or 4-wire Direct connection: 230(400)-240(415)V 63A 400-415V 63A Programmable pulse output RS485 communication Sealable housing and terminal block Externet interfaces: Ethernet communication (NT809-NT891) RS232 communication (NT693)

Energy Meters

download pdf file Three-phase 3 or 4 wire network Input voltage 100-400V (phase-phase) Isolated current input connection by CT/5A Programmable external VT and CT ratio Programmable pulse output RS485 communication Sealable housing and terminal block

Energy Meters

download pdf file [su_table][su_table] Single and three-phase network direct connection three-phase 400-415V single-phase 230-240V Direct connection single and three-phase 100-115V Connection by VT/100 and /110V Isolated current input CT/1A and /5A External interfaces Ethernet communication (NT809-891) RS232 communication (NT693) [/su_table]

Energy Meters

download pdf file Static Meter Active Energy 2 mondule Single-phase network Input voltage 230-240V Input current 5(63)A Pulse output RS485 communication Sealable housing and terminal block

Energy Meters

download pdf file Static Meter Active Energy 2 module Single-phase line Active energy count Voltage input 230V and 240V Current input 5(36)A

Energy Meters

download pdf file [su_table][su_table] AUX Selfsupplied OUTPUT pluses(Wh) FORMAT 1 DIN module CURRENT 5 (45)A VOLTAGE 230V VOLTAGE OPTIONS direct CURRENT OPTIONS direct TYPE Direct connected active (class B) energy meter MAIN single-phase [/su_table] CE1DMID12

Energy Meters

download pdf file [su_table][su_table] AUX Selfsupplied OUTPUT pluses(Wh) FORMAT 1 DIN module CURRENT 5 (32)A VOLTAGE 230V VOLTAGE OPTIONS direct CURRENT OPTIONS direct TYPE Direct connected active energy meter (class 1) MAIN single-phase [/su_table] CE1115A2 CE11165A0